Special Equipment

Article 600, Electric Signs and Outline Lighting

Portable or Mobile Signs

Section 600.10

Portable or mobile signs are covered by Section 600.10. The concern here is that because they're portable or mobile they may be installed in a variety of types of locations. If they are in a wet or damp location, they must have a ground-fault circuit interrupter. (GFCI)

Because the sign's location cannot be known with certainty – it could sometimes be outside and sometimes inside – portable and mobile signs are required to be protected by a ground-fault circuit interrupter that is installed at the factory.

NOTE: This is an unformatted excerpt from our online fire protection training library.